Teleinfo informations¶
Teleinformation data explanation¶
You can find official ERDF informations here : http://www.erdf.fr/medias/DTR_Racc_Comptage/ERDF-NOI-CPT_02E.pdf
Tag | Format | Description |
---|---|---|
ADCO | 12 car. | Electric meter address |
OPTARIF | 4 car. | Tariff option |
ISOUSC | 2 car. unit = ampere | Power subscribed |
BASE | 9 car. unit = Wh | Base option index |
HCHC | 9 car. unit = Wh | Peak hours index |
HCHP | 9 car. unit = Wh | Off peak hours index |
EJP HN | 9 car. unit = Wh | Normal hours index if option = EJP |
EJP HPM | 9 car. unit = Wh | Peak hours index if option = EJP |
PEJP | 2 car. | EJP notice (30 minutes before the period) if option = EJP |
BBR HC JB | 9 car. unit = Wh | Off peak hours index for blue days if option = tempo |
BBR HP JB | 9 car. unit = Wh | Peak hours index for blue days if option = tempo |
BBR HC JW | 9 car. unit = Wh | Off peak hours index for white days if option = tempo |
BBR HP JW | 9 car. unit = Wh | Peak hours index for white days if option = tempo |
BBR HC JR | 9 car. unit = Wh | Off peak hours index for red days if option = tempo |
BBR HP JR | 9 car. unit = Wh | Peak hours index for red days if option = tempo |
PTEC | 4 car. | Current tariff period |
DEMAIN | Tomorrow color if option = tempo | |
IINST | 3 car. unit = A | Instant power |
ADPS | 3 car. unit = A | Warning when the subscribed poower is reached (emmitted only when needed) |
IMAX | 3 car. unit = A | Maximum power |
PAPP | 5 car. unit = VA | Apparent power |
HHPHC | 1 car. | Hourly group |
MOTDETAT | 6 car. | Counter status |
Three phase specific data¶
If you have a 3-phase install, you will have more informations:
- iinst1, iinst2,iinst3 instead of iinst
- imax1, imax2, imax3 instaed of imax
If you use more power than provided on one phase, the information sent by teleinfo will change, and you will receive message with only a few informations :
- ADIR1, ADIR2, ADIR3 : intensity overload on each phase
- IINST1, IINST2, IINST3 : intensity on each phase.