Teleinfo informations

Teleinformation data explanation

You can find official ERDF informations here : http://www.erdf.fr/medias/DTR_Racc_Comptage/ERDF-NOI-CPT_02E.pdf

Tag Format Description
ADCO 12 car. Electric meter address
OPTARIF 4 car. Tariff option
ISOUSC 2 car. unit = ampere Power subscribed
BASE 9 car. unit = Wh Base option index
HCHC 9 car. unit = Wh Peak hours index
HCHP 9 car. unit = Wh Off peak hours index
EJP HN 9 car. unit = Wh Normal hours index if option = EJP
EJP HPM 9 car. unit = Wh Peak hours index if option = EJP
PEJP 2 car. EJP notice (30 minutes before the period) if option = EJP
BBR HC JB 9 car. unit = Wh Off peak hours index for blue days if option = tempo
BBR HP JB 9 car. unit = Wh Peak hours index for blue days if option = tempo
BBR HC JW 9 car. unit = Wh Off peak hours index for white days if option = tempo
BBR HP JW 9 car. unit = Wh Peak hours index for white days if option = tempo
BBR HC JR 9 car. unit = Wh Off peak hours index for red days if option = tempo
BBR HP JR 9 car. unit = Wh Peak hours index for red days if option = tempo
PTEC 4 car. Current tariff period
DEMAIN   Tomorrow color if option = tempo
IINST 3 car. unit = A Instant power
ADPS 3 car. unit = A Warning when the subscribed poower is reached (emmitted only when needed)
IMAX 3 car. unit = A Maximum power
PAPP 5 car. unit = VA Apparent power
HHPHC 1 car. Hourly group
MOTDETAT 6 car. Counter status

Three phase specific data

If you have a 3-phase install, you will have more informations:

  • iinst1, iinst2,iinst3 instead of iinst
  • imax1, imax2, imax3 instaed of imax

If you use more power than provided on one phase, the information sent by teleinfo will change, and you will receive message with only a few informations :

  • ADIR1, ADIR2, ADIR3 : intensity overload on each phase
  • IINST1, IINST2, IINST3 : intensity on each phase.